Quality
 
Certified Quality System as per ISO9001-2000
Follow best quality practices like 5S, TQM, Kaizen & Poka Yoke
In house Product Reliability Testing Facility like:
 
Solvent resistance
(Double rubs acetone test)

1000+

 
Pencil hardness
(Gauge method load on Pencil approx 2000 gm)

4H+

 
Corrosion resistance (polished brass)
(Natural salt spray test as per ASTM B117)

500Hrs.+

 
Abrasion resistance litres sand
(As per ASTM D968 using Ottowa sand)
18+
(litres sand)
 
UV Light Resistance Dyed “Brass”
(Using UV B313 tubes 2 hours UV at 60 deg. C)
Colour ΔE change (CIELAB)
Less than ΔE 2.0
at 500 Hrs.
 
Sweat Resistance cycle
(ANS/BHMA test USA specification)

Pass4

 
Corrosion resistance (Zinc die cast) hours

240+

In house Environmental Test Facility
Salt Spray Chamber
Endurance Rigs
Group Shared Facilities for Ottawa sand, load atmospheric conditions etc.